The door is the first thing you notice: a round slab of steel taller than a man, hinged like the door of a bank vault, with bolts the size of fists around its rim. A worker turns a wheel, the bolts draw back, and the door swings open on its hinge to reveal a dark tunnel lined with rails. On the rails sits a trolley, and on the trolley, wrapped in silver vacuum bag film, is a wing panel — or the curve of a fuselage, or a racing car tub — waiting to be baked. Inside the steel tube, the temperature is about to climb past the boiling point of water, and the pressure will rise to several times the air outside.

Autoclave curing is how the strongest composite parts are made. A part is laid up from carbon fibre cloth soaked in resin, sealed in a vacuum bag, and then placed inside an autoclave — a giant heated pressure vessel — where heat and pressure work together to turn soft cloth into a rigid structure. The heat makes the resin flow and bond; the pressure squeezes out the last pockets of air and presses the fibres tight. Without the autoclave, a carbon fibre part can still be strong, but it will never be as dense, as consistent, or as free of voids as one that has been cured under pressure.

A worker pushing a trolley with a bagged carbon fibre part into a huge industrial autoclave
A bagged part going into the autoclave on its trolley.

How Autoclave Curing Production Works

Step 1: The part is laid up on a mould

Long before the autoclave door closes, the part is built by hand. Sheets of carbon fibre prepreg — cloth already impregnated with uncured resin — are laid onto a mould, one layer at a time, each at a chosen angle. The direction of the fibres decides the direction of the strength, so a part that must resist bending gets most of its fibres running one way, and a part that must resist twisting gets fibres at forty-five degrees. Workers press each layer down with rollers, chasing out air bubbles and making sure the cloth follows the curves of the mould.

Step 2: The lay-up is sealed in a vacuum bag

The mould and its cloth are then sealed inside a vacuum bag made from a heat-resistant film. The bag is taped to the mould around its edges, a vacuum port is fitted, and a pump draws the air out. The atmosphere pressing on the bag squeezes the layers together, forcing out trapped air and holding the fibres tight against the mould. Over the bag go the consumables that make the cure work: a breather cloth that lets air escape evenly, a release film that stops the bag sticking to the part, and sometimes a caul plate — a stiff sheet that presses a flat surface smooth.

Step 3: The bagged part is loaded into the autoclave

The sealed mould is rolled into the autoclave on a trolley that runs on rails, and the vessel’s massive door is closed and locked. An autoclave is a steel cylinder, sometimes thirty metres long, lined with heating elements and fitted with fans that circulate the hot air so the temperature is even from one end to the other. The door seals against a ring of bolts or a quick-locking mechanism, because once the cycle starts, the pressure inside will reach several times atmospheric pressure, and the door must not move a millimetre.

A carbon fibre part sealed inside a vacuum bag on a steel mould with vacuum hoses attached
The bagged part, sealed and leak-tested, ready for the autoclave.

Step 4: Heat and pressure rise on a set recipe

The cure follows a recipe: a programme of temperature and pressure that rises in stages, holds, and then falls again, over several hours. First the temperature climbs gently while the vacuum holds, letting the resin soften and flow into every gap between the fibres. Then the pressure is applied — often six or seven times atmospheric pressure — squeezing the laminate and forcing out the last air and excess resin, which is soaked up by the breather cloth. The temperature holds at the curing point while the resin cross-links and hardens, a chemical change that cannot be undone.

Step 5: The vessel cools and the door opens

Cooling is as carefully controlled as heating. The autoclave is allowed to come down in temperature slowly, under pressure, so the part does not cool faster on the outside than the inside and warp as it shrinks. Only when the temperature has fallen to a safe level is the pressure released and the door opened. The trolley is rolled out, and the first thing the team does is check the bag: it should be tight and intact, a sign that the vacuum held for the whole cycle. A bag that has blown off or torn means the cure may have failed, and the part will be inspected with extra care.

Step 6: De-bagging, inspection, and finishing

The bag, breather, and release film are peeled away, and the part is lifted from the mould. It is inspected first by eye and by hand: the surface should be smooth and glossy on the mould side, with no dry patches, no wrinkles, and no resin-starved areas. Then comes the real inspection. Critical parts are scanned with ultrasound, which can see voids and delaminations hidden inside the laminate, and the results are compared against the standard for that part. A void larger than the limit means the part is rejected or repaired, and every rejection is logged so the factory can trace it back to the lay-up or the cure.

Autoclave Curing Production at a Glance

Feature Detail
Vessel Heated steel pressure cylinder
Typical pressure Several times atmospheric pressure
Cure temperature Well above the boiling point of water
Cycle time Several hours per part
Key consumables Vacuum bag film, breather, release film
Key tests Leak test, thermocouple trace, ultrasound scan

How Much Does Autoclave Curing Cost?

The price is an estimate, because the cost is dominated by the machine itself and the size of the part. A large aerospace autoclave is generally estimated to cost in the region of two to ten million dollars to buy and install, and running a single cure cycle for a large part can cost several thousand dollars in energy, labour, and consumables such as vacuum bagging film, which is used once and thrown away. The process is explained step by step in how autoclave curing works, and the reason it costs so much is set out in why autoclave curing is so expensive. For the metal casting that makes the moulds and tooling for many composite parts, see how superalloy casting is made.

A finished glossy black carbon fibre panel fresh from curing on a factory inspection table
A cured carbon fibre panel on the inspection table, fresh from the autoclave.

A Rare Fact About Autoclave Curing

The word autoclave comes from the Greek auto, meaning self, and the Latin clavis, meaning key — a self-locking device. The first autoclaves were not for composites at all but for cooking and sterilising, and the medical autoclave that sterilises surgical instruments works on exactly the same principle: heat plus pressure inside a sealed steel vessel. The composites industry borrowed the machine wholesale in the second half of the twentieth century, and the largest autoclaves ever built were made to cure the wings of wide-body airliners, vessels so large that a person can walk inside them standing upright.